KaDeck · Kampmann

A shallow unit. More freedom for the ceiling.

KaDeck is a shallow ceiling fan coil for hydronic heating and cooling. Recessed and ceiling-mounted versions provide flexible solutions for offices and spaces with limited ceiling height.

Kampmann KaDeck

Designed around your project

  • The basic unit height is 165 mm; the complete installation space depends on the selected version and connections.
  • Single-sided discharge suits wall positions, while double-sided discharge suits central room positions.
  • Access from below helps with maintenance of the unit and valves.

What matters when selecting the unit?

Choose the correct version for dry or wet cooling. Check dew-point control, condensate drainage and service access; the basic casing height is not the total required installation height.

Product selection with TDC

Send us the room layout, required heating or cooling duty, system temperatures, available installation space and controls requirements. We will help select the equipment and suitable accessories.

Request a quotation Current manufacturer data →

Kampmann documentation and downloads

Dimensions and available versions

The basic casing height is 165 mm. For the 600 mm grid, the selection lists 598 × 165 × 1,198 mm (width × height × length). Other grids and exposed-installation frames must be checked for the specific version.

Technical details

An EC tangential fan and moulded EPP casing distribute air along the ceiling. Versions provide single-sided or double-sided discharge, two-pipe or four-pipe systems and dry or wet cooling. Optional primary-air connections are located at the ends.

Installation and project planning

Recessed or exposed ceiling installation. Single-sided discharge suits a wall position; double-sided discharge suits a central position. Access from below supports servicing. Dry cooling needs dew-point control; wet cooling needs the appropriate unit and drainage.

Benefits

KaDeck is a shallow ceiling fan coil for hydronic heating and cooling. Recessed and ceiling-mounted versions provide flexible solutions for offices and spaces with limited ceiling height.

Configurator

The basic unit height is 165 mm; the complete installation space depends on the selected version and connections. Single-sided discharge suits wall positions, while double-sided discharge suits central room positions. Access from below helps with maintenance of the unit and valves.

An EC tangential fan and moulded EPP casing distribute air along the ceiling. Versions provide single-sided or double-sided discharge, two-pipe or four-pipe systems and dry or wet cooling. Optional primary-air connections are located at the ends.

Technical details:

KaDeck

Recessed or exposed ceiling installation. Single-sided discharge suits a wall position; double-sided discharge suits a central position. Access from below supports servicing. Dry cooling needs dew-point control; wet cooling needs the appropriate unit and drainage.

The basic casing height is 165 mm. For the 600 mm grid, the selection lists 598 × 165 × 1,198 mm (width × height × length). Other grids and exposed-installation frames must be checked for the specific version. Choose the correct version for dry or wet cooling. Check dew-point control, condensate drainage and service access; the basic casing height is not the total required installation height.

Download documents:

  KaDeck - technical catalogue   (7.03 MB)
  Kampmann spezial KaDeck   (1.9 MB)